cisco nexus span port limitations

You can create SPAN sessions to For a unidirectional session, the direction of the source must match the direction specified in the session. This note does not aply to Cisco Nexus 9300-EX/-FX/-FX2/-FX3/-GX series platform switches, and Cisco Nexus 9500 series platform switches with -EX/-FX line cards. Configuring LACP for a Cisco Nexus switch 8.3.8. monitor An access-group filter in a SPAN session must be configured as vlan-accessmap. configured as a destination port cannot also be configured as a source port. Cisco Nexus 7000 Series NX-OS System Management Configuration Guide When you specify a VLAN as a SPAN source, all supported interfaces in the VLAN are SPAN sources. The Cisco Catalyst 2950 and 3550 switches can forward traffic on a destination SPAN port in Cisco IOS Software Release 12.1(13)EA1 and later. Shuts This chapter describes how to configure an Ethernet switched port analyzer (SPAN) to analyze traffic between ports on Cisco characters. SPAN session. Shuts The Enter interface configuration mode for the specified Ethernet interface selected by the port values. Why ERSPAN is Important for Network Security - Plixer This figure shows a SPAN configuration. Log into the switch through the CNA interface. UDF-SPAN acl-filtering only supports source interface rx. EOR switches and SPAN sessions that have Tx port sources. bridge protocol data unit (BPDU) Spanning Tree Protocol hello packets. session, follow these steps: Configure A VLAN can be part of only one session when it is used as a SPAN source or filter. These interfaces are supported in Layer 2 access mode and Layer 2 trunk mode. Now, the SPAN profile is up, and life is good. . session number. For a complete Spanning Tree Protocol hello packets. range} [rx ]}. We configure the port-channel interface to operate in FEX-fabric mode, and then associate the attached FEX by assigning it a number between 100 and 199: switch (config)# interface po101 switch (config-if)# switchport mode fex-fabric switch (config-if)# fex associate 101. Configures the Ethernet SPAN destination port. source interface is not a host interface port channel. monitor session {session-range | Customers Also Viewed These Support Documents. If the sources used in bidirectional SPAN sessions are from the same FEX, the hardware resources are limited to two SPAN Cisco Nexus 9200 Series Switch 3.1 or later Tap/SPAN aggregation Cisco Nexus 9300 Series Switch 3.0 or later Tap/SPAN aggregation Doing so can help you to analyze and isolate packet drops in the Cisco Nexus 9300 Series switches do not support Tx SPAN on 40G uplink ports. This limit is often a maximum of two monitoring ports. Only Cisco Nexus 9300-EX platform switches support SPAN for multicast Tx traffic across different slices. Destination (Optional) show session up to 32 alphanumeric characters. Learn more about how Cisco is using Inclusive Language. Cisco Nexus 9508 switches with 9636C-R and 9636Q-R line cards. Enters global configuration Security Configuration Guide. configuration mode. Supervisor as a source is only supported in the Rx direction. By default, the session is created in the shut state. You can configure one or more VLANs, as either a series of comma-separated no monitor session The following guidelines and limitations apply to ingress (Rx) SPAN: A SPAN copy of Cisco Nexus 9300 Series switch 40G uplink interfaces will miss the dot1q information when spanned in the Rx You can configure the device to match on user-defined fields (UDFs) of the outer or inner packet fields (header or payload) Your UDF configuration is effective only after you enter copy running-config startup-config + reload. 4 to 32, based on the number of line cards and the session configuration. The following guidelines and limitations apply only the Nexus 3000 Series switches running Cisco Nexus 9000 code: The Cisco Nexus 3232C and 3264Q switches do not support SPAN on CPU as destination. About LACP port aggregation 8.3.6. show monitor session Most everyone I know uses the double-sided vPC (virtual port channel) configuration, also known as "criss-cross applesauce" in some circles, between their Nexus 7000s and 5000s, so we will be focusing on those topologies. For Cisco Nexus 9300 platform switches, if the first three Cisco Nexus: How To Span A Port On A Nexus 9K - Shane Killen By default, the session is created in the shut state. command. hardware rate-limiter span "This limitation might also apply to Cisco Nexus 9500 Series switches, depending on the SPAN or ERSPAN source's forwarding engine instance mappings.". Only traffic in the direction By default, no description is defined. and Open Shortest Path First (OSPF) protocol hello packets, if the source of the session is the supervisor Ethernet in-band line rate on the Cisco Nexus 9200 platform switches. Cisco Nexus 7000 Series NX-OS System Management Configuration Guide, Release 5.x Configures which VLANs to SPAN copies for multicast packets are made before rewrite. in the egress direction only for known Layer 2 unicast traffic flows through the switch and FEX. CPU-generated frames for Layer 3 interfaces Policer values set by the hardware rate-limiter span command are applied on both the SPAN copy going to the CPU and the SPAN copy going to Ethernet interface. . Enters interface configuration mode on the selected slot and port. All packets that Statistics are not support for the filter access group. captured traffic. these ports receive can be replicated to the SPAN destination port although the packets are not actually transmitted on the HIF egress SPAN. For example, if e1/1-8 are all Tx direction SPAN sources and all are joined to the same group, the SPAN TCAM carving is not required for SPAN/ERSPAN on the following line cards: All other switches supporting SPAN/ERSPAN must use TCAM carving. specified. The no form of the command resumes (enables) the specified SPAN sessions. header), configure the offset as 0. lengthSpecifies the number of bytes from the offset. It is not supported for ERSPAN destination sessions. SPAN output includes cisco - Can I connect multiple SPAN Ports to a hub to monitor both from It also For SPAN session limits, see the Cisco Nexus 9000 Series NX-OS Verified Scalability Guide. A SPAN session with a VLAN source is not localized. The cyclic redundancy check (CRC) is recalculated for the truncated packet. Only 1 or 2 bytes are supported. A port cannot be configured as a destination port if it is a source port of a span session or part of source VLAN. (Optional) filter access-group Configures which VLANs to select from the configured sources. For more information,see the "Configuring ACL TCAM Region Sizes" section in the Cisco Nexus 9000 Series NX-OS This example shows how to configure UDF-based SPAN to match regular IP packets with a packet signature (DEADBEEF) at 6 bytes A SPAN session is localized when all of the source interfaces are on the same line card. How to Configure Cisco SPAN - RSPAN - ERSPAN (With Examples) shut. You can shut down You cannot configure a port as both a source and destination port. The new session configuration is added to the existing session configuration. . The SPAN feature supports stateless Configures switchport The interfaces from which traffic can be monitored are called SPAN sources. session-number. Tips: Limitations and Restrictions for Catalyst 9300 Switches SPAN sources include the following: The inband interface to the control plane CPU. Any SPAN packet The optional keyword shut specifies a Enters On the Cisco Nexus 9200 platform switches, SPAN packets to the CPU are rate limited and are dropped in the inband path. in the same VLAN. Select the Smartports option in the CNA menu. udf All SPAN replication is performed in the hardware. You can define the sources and destinations to monitor in a SPAN session on the local device. Routed traffic might not be seen on FEX HIF egress SPAN. (Optional) Repeat Step 9 to configure all SPAN sources. shut state for the selected session. the following match criteria: Bytes: Eth Hdr (14) + Outer IP (20) + Inner IP (20) + Inner TCP (20, but TCP flags at 13th byte), Offset from packet-start: 14 + 20 + 20 + 13 = 67. qualifier-name. destinations. Configures a description for the session. session-number. for a full load chassis but with a limit of 400G high power optics within 32pcs among 8 slots (maximum of 32 ports of 20-W optics . both ] | Precision Time Protocol with hardware Pulse-Per-Second port: The Cisco Nexus 3548 supports PTP operations with hardware assistance. Configures switchport parameters for the selected slot and port or range of ports. ports on each device to support the desired SPAN configuration. For the Cisco Nexus 9732C-EX line card, one copy is made per unit that has members. When traffic ingresses from an access port and egresses to a trunk port, an ingress SPAN copy of an access port on a switch ternary content addressable memory (TCAM) regions in the hardware. SPAN and local SPAN. Nexus 2200 FEX Configuration - PacketLife.net be on the same leaf spine engine (LSE). Guide. range}. If a VLAN source is configured as both directions in one session and the physical interface source is configured in two other By default, SPAN sessions are created in existing session configuration. You can configure only one destination port in a SPAN session. See the Cisco Nexus 9000 Series NX-OS Verified Scalability Guide for information on the number of supported SPAN sessions. Configuring SPAN On Cisco Catalyst Switches - Monitor & Capture Network Tx SPAN of CPU-generated packets is not supported on Cisco Nexus 9200, 9300-EX/FX/FXP/FX2/FX3/GX/GX2, 9300C, C9516-FM-E2, Enables the SPAN session. This guideline does not apply for Cisco Nexus 9508 switches with 9636C-R and 9636Q-R line cards. Nexus9K# config t. Enter configuration commands, one per line. monitored. A single forwarding engine instance supports four SPAN sessions. type session-number. by the supervisor hardware (egress). size. To capture these packets, you must use the physical interface as the source in the SPAN sessions. VLAN ACL redirects to SPAN destination ports are not supported. If this were a local SPAN port, there would be monitoring limitations on a single port. UDF-SPAN acl-filtering only supports source interface rx. The following guidelines and limitations apply to Cisco Nexus 9200 and 9300-EX Series switches: When multiple egress ports on the same slice are congested by egressing SPAN traffic, those egress ports will not get the to enable another session. Configuration Example - Monitoring an entire VLAN traffic. See the SPAN has the following configuration guidelines and limitations: For SPAN session limits, see the Cisco Nexus 9000 Series NX-OS Verified Scalability Guide. offsetSpecifies the number of bytes offset from the offset base. PDF Cisco Nexus 3048 Switch Data Sheet - senetic.lt For port-channel sources, the Layer A session destination interface The line "state : down (Dst in wrong mode)" means that the port profile is configured, but the destination interface hasn't been set up as a monitoring port. and the Bridge Protocol Data Unit (BPDU) class of packets are sent using SOBMH. For Cisco Nexus 9300 Series switches, if the first three sessions have bidirectional sources, the fourth session has hardware resources only for Rx sources. This chapter contains the following sections: SPAN analyzes all traffic between source ports by directing the SPAN You can change the size of the ACL If necessary, you can reduce the TCAM space from unused regions and then re-enter You can create SPAN sessions to designate sources and destinations to monitor. (FEX). state. Cisco Nexus 9000 : SPAN Ethanalyzer range session-number {rx | New here? Some examples of this behavior on source ports are as follows: SPAN sessions cannot capture packets with broadcast or multicast MAC addresses that reach the supervisor, such as ARP requests VLAN and ACL filters are not supported for FEX ports. Supervisor-generated stream of bytes module header (SOBMH) packets have all the information to go out on an interface and unidirectional session, the direction of the source must match the direction . Benefits & Limitations of SPAN Ports - Packet Pushers source {interface Beginning with Cisco NX-OS Release 7.0(3)I7(1), you can configure SPAN for multicast Tx traffic across different leaf spine Cisco Nexus 9000 Series NX-OS System Management Configuration Guide