Xcel Energy (the Company) has been directed to complete its hosting capacity analysis in service of Xcel customers and grid stakeholders. Subject to your specific situation, ComEd's response may require further action to be taken and/or further expense to be incurred by you in order to complete the interconnection. This hosting capacity data is provided for informational purposes only and is nota substitute for the established interconnection application process. Solar tower of power shows benefits of vertical installations, Court rules that inverter sizing guides grid connection, California pulls the plug on rooftop solar, Retaining value for solar customers under California NEM 3.0 rule change, U.S. Commercial Solar Guy is a commercial solar developer, general contractor, and consultant. This site uses cookies. The Commission should order Xcel Energy to publish all criteria violations on the HCA map. You may be trying to access this site from a secured browser on the server. Also, the map is taken from data as of a point in time and updated as of the date indicated in the pop-up display on the map, and therefore may not reflect current conditions in a given area. E999/CI20-800, rule whether Xcel Energy must comply with Order Point 12 of the July 2020 order. For example, a recent 200 kWac project in Rhode Island learned when the interconnection application was submitted that no additional solar power was on either the local circuit or at the substation. Properly designed, the hosting capacity maps offer the ability to look closely at our power grid resources. Please contact our Customer Care Center if you have questions. It divides the ComEd service territory into townships (6 miles X 6 miles). Xcel has since written should the Commission determine it is in the public interest for the Company to advance and mature the HCA to be conducted more frequently and/or to integrate with the interconnection process, the Company would refine cost and timing estimates. The Commission should accept Xcel Energys 2020 Hosting Capacity Analysis Report, but we submit the following concerns about the Report and suggest additional development to advance the common goals of customers and the Commission. We also offer comprehensive global coverage of the most important solar markets worldwide. Owner signs deal, $2,5000 payment made for PE-stamped one line & interconnection application 3. Read the report, and find all of our resources and reporting on chain dollar stores here. Please be mindful of our community standards. ArcGIS Web Application Electricity Forum publishes Electricity Today T&D Magazine and Intelligent Power Today Industrial Electrical Magazine. It does not appear on display pages. Locational System Relief Value, or LSRV, is one component of the Value Stack that makes up compensation for Distributed Energy Resources (DER) under the Value of DER structure (pdf). The Institute for Local Self-Reliance (ILSR) respectfully submits the following comments on Xcel Energys 2020 Hosting Capacity Report. Share to Facebook. Featured photo credit: Victoria Catterson via Flickr (CC BY 2.0). As it turned out, the larger-scale ground mount project was moving slowly due to local resistance. We continue to believe such an approach would risk grid security and customer privacy, confidentiality and security as described in more detail in Section III below and in attachment E. Therefore, we again provide a heat map view of available hosting capacity. Solar hosting capacity is the gold to be found in these utility treasure maps. Select one or more editions for targeted, up to date information delivered straight to your inbox. For these reasons, the installed and queued DG values in the data pop-ups have been included and will be updated on a monthly basis. Notify me of follow-up comments by email. A complete copy of Part 466 is available on the link provided below. These tools make it so every stakeholder in the process is able to work more efficiently and save the entire system precious time + money. The IREC paper describes how some utilities have worked to ensure accurate inputs to their hosting capacity analysis, and use automated flags to identify anomalous modeling results. Integrating hosting capacity analysis with the interconnection process is not only possible, it is already being done. Here are links to several Hosting Capacity Maps intended for solar developers. Processing: Hosting Capacity map added on August 11, 2017. Required fields are marked *. The Electricity Forum (In Canada)
A legend can also be found in the top left corner of the map. The watchword is actionable. If the maps arent actionable (b/c theyre not accurate) they re actually worse than useless. According to ComEds description, Hosting Capacity is an estimate of the amount of DER [distributed energy resources] that may be accommodated under current configurations at the overall circuit level without significant system upgrades to address adverse impacts to power quality or reliability. This website will enable developers and local decision makers to estimate how much solar could be installed by township, sections and fractions of sections as small as mile by mile. Peak and Minimum Load Duration Curves The Commission then fined the Company one million dollars (about 0.0007 of their annual 2020 revenue). PG&Es initial solar hosting capacity map showed lots of red for Monterey, California, and was later corrected to show lots of green, says IREC. Get information on current projects and opportunities. The pre-application report produced by ComEd is non-binding and does not confer any rights; the potential applicant must file an application before it can interconnect with the ComEd system. Minnesota solar companies filed 129 interconnection complaints in 2019. View the Interconnection Queue. 216B.2425, subdivision 8, to support the continued development of distributed generation resources.. A potential applicant may submit a formal written request form along with a non-refundable fee for a pre-application report on a proposed project at a specific site. ComEd's electric distribution system is dynamic and ComEd will provide periodic updates to the hosting capacity map. PECO is committed to providing safe and reliable service for customers while also supporting the interconnection of customer-owned renewable energy and Distributed Energy Resources (DER), like solar. ComEd anticipates that the Interconnection Queue data will typically be updated monthly. email the ComEd DER Interconnection team. The tool functions well, as intended, to provide developers of large DERs early insight into grid locational hosting capacity. I was involved in various CPUC regulatory proceedings on these maps and made the same kinds of comments frequently. Your personal data will only be disclosed or otherwise transmitted to third parties for the purposes of spam filtering or if this is necessary for technical maintenance of the website. Legal Notice Terms and Conditions Privacy Policy pv magazine 2023, Welcome to pv magazine USA. Stay informed. The hosting capacity analysis is conducted under current configurations. This is necessary, because developer complaints have continued to the present. <>/Font<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 765 990] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>>
Save my name, email, and website in this browser for the next time I comment. The IREC paper advises utilities to be pro-active in ensuring the accuracy of the mapsto save time for utility customers siting and designing new solar installations, and also for utility engineers performing interconnection studies. 1885 Clements Rd, Unit 218
These forecasts have uncertainties, such as weather and hourly load curves, as well as the typical inherent forecasting error, including, but not limited to economic drivers, customer decisions and/or behavior, and forecasted DERs. What makes feeder locations a greater risk threat in Minnesota than in New York or California? Each circuit's hosting capacity is determined by evaluating impacts of DER along the three phase distribution mainline. As for load capacity, it is important to understand that load capacity varies hourly throughout the year, depending on demand; if load capacity shows up as zero at one location and time, that doesnt mean that it is zero year-round. These network curves shows a representative load profile of the forecasted hourly peak (maximum) loads for 2018, and a representative load profile on light loads (minimum load) for the networks (based on 2017 data). Control systems Monitor your operations and set temperature points and fan speeds to optimize savings. Have questions about how to utilize and navigate the platform? We publish electrical technical handbooks and associated digital magazine advertising supplements. This tool isnt applicable for the vast majority of DER project planning (around 98%) in SDG&Es service territory. Supporters agreed that the Companys participation in greater inter-developer transparency could facilitate cost-sharing in line upgrades and would be an improvement from the current cost-causer pays model. Don't miss a single report, infographic, or podcast! The hosting capacity map utilizes the United States Public Land Survey System (US PLSS) to present results. Introduction. Inaccurate results were also found in a different type of hosting capacity map produced by PG&E and two other California utilities, the IREC paper says: maps showing the capacity for added load on a circuit, such as electric vehicles. The Interconnection Queue Report provides the following minimum information for all Distributed Generation (Excluding Level 1 Applications) or Distributed Storage Resource Projects for which a queue position has been assigned: Each substation and feeder where an interconnection will be made is identified in the reported data by a unique index number assigned for the purpose of reporting interconnection queue information and not by any geographic or operational designation or description. 4 0 obj
Please contact our Customer Care Center if you have questions. This map does not restrict applications from being submitted for a particular circuit, but rather is a tool to inform applicants on the amount of generation a circuit has the potential to host without the need for significant system upgrades at the customer's cost. To similarly incorporate hosting capacity analysis into the Xcel interconnection processs fast track screens would support the development of distributed energy resources in Minnesota by reducing costs and time for project development, and would direct project development to locations with existing grid capacity. ILSR asks that the Commission provide the Company more direction, in the form of deadlines to use HCA in initial or supplemental interconnection review (in the next 18-24 months) and automating at least a portion of interconnection proceedings (by 2025) as well as staff-facilitated working groups to guide implementation. Utility National Grid operates in Rhode Island and illustrates local line capacities with its HCA map. In Why Utilities in Minnesota and Other States Need to Plan for More Competition, ILSR found that Xcel Energys forecasts for distributed solar, including customer-sited and community solar, are significantly low in light of existing trends and comparative models. It may be easy to under-invest in a robust hosting capacity analysis if the utility (and regulators) under-count potential distributed solar development. L1W3V4
Every interconnection location must be specifically assessed through the formal interconnection process. We adjust the load shapes to the individual network peak demand and energy send-out forecasts, including the projected DER impacts, such that the forecast includes the impact of load modifiers. However, the interconnection process stands to gain much more from hosting capacity analysis. Where applicable, ComEd will offer an interconnection agreement. The Commissions July 2020 order, in response to Xcel Energys 2019 Hosting Capacity Analysis (HCA) Report, found that improved and additional information will be necessary in future reports and provided the Commissions direction for future HCA reports. In this order, the Commission determined that Xcel should publish the actual locations of distribution system lines because giving customers and developers access to more precise data would allow them to make informed decisions about whether to pursue a project before investing significant time or resources into the planning process. Order Point 12 required Xcel Energy to do so in its 2020 Hosting Capacity Report. Californias process to incorporate hosting capacity analysis into the interconnection process began in 2014, so we understand that this will take some time. You may submit a formal request for DER interconnection at a specific site online. Whether youre a customer, contractor, or developer, our interactive maps can help you identify potential sites for private generation. Source: Data has been sourced from multiple National Grid groups and incorporated into this Portal by National Grid's IMAP team. A decade ago, resources for scouting viable locations for new distributed energy resources (DER) simply did not exist. Please enable JavaScript on your browser and try again. You may be trying to access this site from a secured browser on the server. No matter the facility type, you can improve the overall energy efficiency of your IT room and keep your computer equipment running while also saving money. This process is automatic. The resulting tools are like treasure maps for solar developers. Without offering an explanation, when the final interconnection for the 200 kW project was approved, the utility assessed no new fees. Washington, DC and part of Maryland: Potomac Electric Power Company map; Last year, ComEd in Illinois also published a hosting capacity map.